Operation CHARM: Car repair manuals for everyone.

P0443




COMPONENT DESCRIPTION
The EVAP canister purge volume control solenoid valve uses a ON/OFF duty to control the flow rate of fuel vapor from the EVAP canister. The EVAP canister purge volume control solenoid valve is moved by ON/OFF pulses from the ECM. The longer the ON pulse, the greater the amount of fuel vapor that will flow through the valve.

Consult-II Reference Value In Data Monitor Mode:






On Board Diagnosis Logic
Malfunction is detected when an improper voltage signal is sent to ECM through the valve.

Possible Cause
- Harness or connectors (The valve circuit is open or shorted.)
- EVAP canister purge volume control solenoid valve

DTC Confirmation Procedure

NOTE: If "DTC Confirmation Procedure" has been previously conducted, always turn ignition switch "OFF" and wait at least 10 seconds before conducting the next test.

TESTING CONDITION:
Before performing the following procedure, confirm battery voltage is more than 11 V at idle.




WITH CONSULT-II
1. Turn ignition switch "ON".
2. Select "DATA MONITOR" mode with CONSULT-II.
3. Start engine and let it idle for at least 13 seconds.
4. If 1st trip DTC is detected, go to "Diagnostic Procedure" below.

WITH GST
Follow the procedure "WITH CONSULT-II" above.

EC-PGC/V-01:




EC-PGC/V-01 Connector View:




ECM Terminals And Reference Value:




Wiring Diagram

Diagnostic Procedure

Diagnostic Procedure Steps 1 - 2:




Diagnostic Procedure Steps 3 - 5:




Diagnostic Procedure Steps 6 - 7: