P0446
Component Description
The EVAP canister vent control valve is located on the EVAP canister and is used to seal the canister vent.
This solenoid valve responds to signals from the ECM. When the ECM sends an ON signal, the coil in the solenoid valve is energized. A plunger will then move to seal the canister vent. The ability to seal the vent is necessary for the on board diagnosis of other evaporative emission control system components.
This solenoid valve is used only for diagnosis, and usually remains opened.
When the vent is closed, under normal purge conditions, the evaporative emission control system is depressurized and allows "EVAP Control System" diagnoses.
Consult-II Reference Value In Data Monitor Mode:
On Board Diagnosis Logic
Malfunction is detected when an improper voltage signal is sent to ECM through EVAP canister vent control valve.
Possible Cause
- Harness or connectors (The valve circuit is open or shorted.)
- EVAP canister vent control valve
DTC Confirmation Procedure
NOTE: If "DTC Confirmation Procedure" has been previously conducted, always turn ignition switch "OFF" and wait at least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm battery voltage is more than 11 V at idle.
WITH CONSULT-II
1. Turn ignition switch "ON".
2. Select "DATA MONITOR" mode with CONSULT-II.
3. Start engine and wait at least 8 seconds.
4. If 1st trip DTC is detected, go to "Diagnostic Procedure" below.
WITH GST
Follow the procedure "WITH CONSULT-II" above.
EC-VENT/V-01:
EC-VENT/V-01 Connector View:
ECM Terminals And Reference Value:
Wiring Diagram
Diagnostic Procedure