Operation CHARM: Car repair manuals for everyone.

P1165







Component Description
The swirl control valve control vacuum check switch detects vacuum signal to the swirl control valve, and sends "ON" or "OFF" signal to the ECM.

When vacuum is supplied to the valve, the swirl control valve control vacuum check switch sends "OFF" signal to the ECM. The swirl control valve control vacuum check switch is not used to control the engine system, it is used for on board diagnosis.

Consult-II Reference Value In Data Monitor Mode:






On Board Diagnosis Logic
Malfunction is detected when the swirl control valve control vacuum check switch remains "OFF" under specified engine conditions.

Possible Cause
- Harness or connectors
(Swirl control valve control vacuum check switch circuit is open.)
- Hoses
(Hoses are clogged or connected incorrectly.)
- Swirl control valve control solenoid valve
- Swirl control valve control vacuum check switch
- Swirl control valve actuator

DTC Confirmation Procedure

NOTE: If "DTC Confirmation Procedure" has been previously conducted, always turn ignition switch "OFF" and wait at least 10 seconds before conducting the next test.

TESTING CONDITION:
For best results, perform the test at a temperature above 5 °C (41 °F).




WITH CONSULT-II
1. Turn ignition switch "OFF" and wait at least 10 seconds.
2. Turn ignition switch "ON".
3. Select "DATA MONITOR" mode with CONSULT-II and wait at least 5 seconds.
If 1st trip DTC is detected, go to "Diagnostic Procedure" below.

WITH GST
Follow the procedure "WITH CONSULT-II" above.

EC-S/VCSW-01:




EC-S/VCSW-01 Connector View:




ECM Terminals And Reference Value:




Wiring Diagram

Diagnostic Procedure

Diagnostic Procedure Steps 1 - 3:




Diagnostic Procedure Steps 4 - 5:




Diagnostic Procedure Step 6:




Diagnostic Procedure Steps 7 - 8: