Without Scan Tool
Meter/Gauge Operation ODO/Trip Meter Segment CheckSELF-DIAGNOSIS FUNCTION
Odo/trip meter (board computer) segment operation can be checked in self-diagnosis mode.
Meters/gauges can be checked in self-diagnosis mode.
HOW TO ALTERNATE DIAGNOSIS MODE
1. Turn the ignition switch ON, and switch the odometer/trip meter to "trip A" or "trip B".
NOTE: If the diagnosis function is activated with the trip meter A displayed, the mileage on the trip meter A will indicate 000.0 miles, but the actual trip mileage will be retained. (Trip B operates the same way.)
2. Turn the ignition switch OFF.
3. While pushing the odo/trip meter switch, turn the ignition switch ON again.
4. Check that the trip meter displays "000.0".
5. Push the odo/trip meter switch at least 7 times within 7 seconds.
6. All the segments on the odo/trip meter illuminate, and simultaneously the low-fuel warning lamp indicator illuminates. At this time, the unified meter control unit is turned to diagnosis mode.
NOTE: If any of the segments is not displayed, replace the combination meter.