Air Cleaner Housing: Service and Repair
AIR CLEANER AND AIR DUCTRemoval and Installation
REMOVAL
1. Disconnect the mass air flow sensor electrical connector.
2. Disconnect the tube clamp at the electronic throttle control actuator and the fresh air intake tube.
3. Remove air cleaner to electronic throttle control actuator tube, air cleaner case (upper), with mass air flow sensor attached.
4. Remove mass air flow sensor from air cleaner case (upper), as necessary.
CAUTION: Handle the mass air flow sensor with care:
^ Do not shock it.
^ Do not disassemble it.
^ Do not touch the internal sensor.
5. Remove the resonator in the fender, as necessary.
INSTALLATION
Installation is in the reverse order of removal.
^ Attach each joint according to the alignment marks made during removal. Screw all clamps firmly.