Without Scan Tool
OBD-II SELF-DIAGNOSTIC PROCEDURE (WITH GST)Refer to "Generic Scan Tool (GST) Function". Reading Diagnostic Trouble Codes
OBD-II SELF-DIAGNOSTIC PROCEDURE (NO TOOLS)
Refer to "Malfunction Indictor Lamp (MIL)". Malfunction Indicator Lamp (MIL)
TCM SELF-DIAGNOSTIC PROCEDURE (NO TOOLS)
1. CHECK A/T CHECK (POSITION) INDICATOR LAMP
1. Move selector lever to P position. Start engine and warm it up to normal engine operating temperature.
2. Turn ignition switch to OFF position.
3. Wait 5 seconds.
4. Turn ignition switch to ON position. (Do not start engine.)
5. Does A/T check (position) indicator lamp come on for about 2 seconds?
Yes or No
Yes >> GO T02.
No >> Stop procedure. Perform "1. A/T Check (Position) Indictor Lamp Does Not Come On" before proceeding.
2. JUDGEMENT PROCEDURE STEP 1
1. Turn ignition switch to OFF position.
2. Turn ignition switch to ON position. (Do not start engine.)
3. Depress the brake pedal, then move gear selector lever from P to D position.
4. Wait 3 seconds.
5. Move selector lever to 2 position.
6. Release brake pedal.
>> GO TO 3.
3. JUDGEMENT PROCEDURE STEP 2
1. Move selector lever to 1 position.
2. Depress brake pedal.
3. Depress accelerator pedal fully and release it.
4. The A/T check (position) indicator lamp will begin to flash.
>>GO T0 4.
4. CHECK SELF-DIAGNOSTIC CODE
Check A/T check (position) indicator lamp.
Refer to "JUDGEMENT OF SELF-DIAGNOSIS CODE".
>> DIAGNOSIS END
JUDGEMENT OF SELF-DIAGNOSIS CODE