Operation CHARM: Car repair manuals for everyone.

Air Bag Control Module: Service and Repair

Diagnosis Sensor Unit

REMOVAL AND INSTALLATION

CAUTION:
- Before servicing SRS, turn the ignition switch off, disconnect both battery cables and wait at least 3 minutes.
- Do not use old bolts after removal; replace with new ones.
- Check diagnosis sensor unit for proper installation.
- Check diagnosis sensor unit to ensure it is free of deformities, dents, cracks or rust. If they show any visible signs of damage, replace them with new ones.
- Check diagnosis sensor unit brackets to ensure they are free of deformities or rust.
- Replace diagnosis sensor unit if it has been dropped or sustained an impact.
- After replacement of diagnosis sensor unit, perform self-diagnosis for SRS. Refer to SRS Operation Check for details. [1][2]Component Tests and General Diagnostics




1. Disconnect driver, passenger and side air bag module connectors. Also, disconnect seat belt pre-tensioner connector.
2. Remove console box. Refer to Instrument Panel Assembly.
3. Disconnect diagnosis sensor unit connector.
4. Remove ground bolt and also remove bolts from diagnosis sensor unit.
Then remove the diagnosis sensor unit.

NOTE:
- To install, reverse the removal procedure sequence.