4. ABS Actuator and Electric Control Unit Power and Ground Systems
INSPECTION PROCEDURE1. SELF-DIAGNOSIS RESULT CHECK
Check self-diagnosis results.
Self-diagnosis results
LOW BATTERY VOLTAGE
Is the above displayed in the self-diagnosis display items?
YES >> GO TO 2.
NO>> Inspection End
2. CONNECTOR INSPECTION
1. Disconnect the VDC/TCS/ABS control unit connector E118 and check the terminal for deformation, disconnection, looseness, and so on, If there is an error, repair or replace the terminal.
2. Securely reconnect the connector and re-conduct self-diagnosis.
OK or NG
OK >> The connector terminal contact is loose, damaged, open or shorted.
NG >> GO TO 3.
3. ABS ACTUATOR AND ELECTRIC UNIT POWER AND GROUND CIRCUIT INSPECTION
Disconnect ABS actuator and electric unit connector E51. Check continuity and voltage between connector terminals and ground.
OK or NG
OK >> Check battery (terminal looseness, power drop, etc.) Error. If there is an error, make repairs.
NG >> Corresponding harness circuit error. Repair the circuit.