Displaying & Reading Trouble Codes
METER/GAUGES OPERATION AND ODO/TRIP METERHOW TO ALTERNATE DIAGNOSIS MODE
1. While pushing the odo/trip meter switch, turn ignition switch ON.
2. Check that the trip meter displays "0000.0".
3. Push the odo/trip meter switch at least 3 times. (Within 7 seconds after the ignition switch is turned ON.)
4. All the segments on the trip computer illuminate. At this time, the unified meter control unit is turned to diagnosis mode.
5. Push the odo/trip meter switch. Each meter/gauge should indicate as shown in the figure while pushing odo/trip meter switch.