Operation CHARM: Car repair manuals for everyone.

CONSULT-II Function




CONSULT-II

CONSULT-II BASIC OPERATION

CAUTION: If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be detected in self-diagnosis depending on control unit which carry out CAN communication.




1. With the ignition switch OFF, connect CONSULT-II and CONSULT-II CONVERTER to the data link connector, then turn the ignition switch ON.




2. Touch "START (NISSAN BASED VHCL)".




3. Touch "IPDM E/R" on "SELECT SYSTEM" screen.
If "IPDM E/R" is not displayed, go to "CONSULT-II Data Link Connector (DLC) Circuit".




4. Select the desired part to be diagnosed on the "SELECT DIAG MODE" screen.

SELF-DIAG RESULTS

Operation Procedure
1. Touch "SELF-DIAG RESULTS" on "SELECT DIAG MODE" screen.
2. Check display content in self-diagnostic results.

Display Item List:




Display Item List

NOTE: The details for display of the period are as follows:
- CRNT: Error currently detected with IPDM E/R.
- PAST: Error detected in the past and memorized with IPDM E/R.

DATA MONITOR

Operation Procedure
1. Touch "DATA MONITOR" on "SELECT MONITOR ITEM " screen.




2. Touch "ALL SIGNALS", "MAIN SIGNALS" or "SELECT FROM MENU" on the "DATA MONITOR" screen.
3. Touch "START".
4. Touch the required monitoring item on "SELECT ITEM MENU". In "ALL SIGNALS", all items are monitored. In "MAIN SIGNALS", predetermined items are monitored.
5. Touch "RECORD" while monitoring to record the status of the item being monitored. To stop recording, touch "STOP".

All Items, Main Items, Select Item Menu:




All Items, Main Items, Select Item Menu

NOTE:
- Perform monitoring of IPDM E/R data with the ignition switch ON. When the ignition switch is at ACC, the display may not be correct.
- "FR FOG REQ" and "OIL P SW" items are displayed, but they cannot be monitored.
- Only the vehicle which day time light system is mounted with operates.

CAN DIAGNOSIS SUPPORT MONITOR

Operation Procedure
1. Touch "DATA MONITOR" on "SELECT MONITOR ITEM" screen.
2. Touch "CAN DIAG SUPPORT MNTR" on the "DATA MONITOR" screen.
3. Touch "START".
4. Touch "RECORD" while monitoring to record the status of the item being monitored. To stop recording, touch "STOP".






NOTE: The details for display of the CAN status are as follows:
- 0: Normal
- 1-40: Error detected in the past and memorized with IPDM E/R.

ACTIVE TEST

Operation Procedure
1. Touch "ACTIVE TEST" on "SELECT DIAG MODE" screen.
2. Touch item to be tested, and check operation.
3. Touch "START".
4. Touch "STOP" while testing to stop the operation.






NOTE:
- The cornering lamp items are displayed, but they cannot be tested.
- The fog lamp items are displayed, but they cannot be tested.