CONSULT-II Function
CONSULT-II Function
CONSULT-II executes the following functions by combining data reception and command transmission via the CAN communication lines from the IPDM E/R.
CONSULT-II BASIC OPERATION
CAUTION: If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be detected in self-diagnosis depending on control unit which carry out CAN communication.
1. With the ignition switch OFF, connect "CONSULT-II" and "CONSULT-II CONVERTER" to the data link connector, then turn ignition switch ON.
2. Touch "START (NISSAN BASED VHCL)".
3. Touch "IPDM E/R" on "SELECT SYSTEM" screen.
- If "IPDM E/R" is not displayed, print "SELECT SYSTEM" screen, then refer to "Precautions for CAN System".
4. Select "SELF-DIAG RESULTS" or "DATA MONITOR".
SELF-DIAGNOSTIC RESULTS
Operation Procedure
1. Touch "SELF-DIAG RESULTS" on "SELECT DIAG MODE" screen.
2. Self-diagnosis results are displayed.
Display Item List
NOTE:
The details for display of the period are as follows:
- CRNT: Error currently detected with IPDM E/R.
- PAST: Error detected in the past and placed in IPDM E/R memory.
DATA MONITOR
Operation Procedure
1. Touch "DATA MONITOR" on "SELECT DIAG MODE" screen.
2. Touch "ALL SIGNALS", "MAIN SIGNALS" or "SELECT FROM MENU" on the "DATA MONITOR" screen.
3. Touch "START".
4. Touch the required monitoring item on "SELECT ITEM MENU".
5. Touch "RECORD" while monitoring to record the status of the item being monitored. To stop recording, touch "STOP".
All Signals, Main Signals, Select From Menu
CAN DIAGNOSIS SUPPORT MONITOR
Operation Procedure
1. Touch "DATA MONITOR" on "SELECT MONITOR ITEM" screen.
2. Touch "CAN DIAG SUPPORT MNTR" on the "DATA MONITOR" screen.
3. Touch "START".
4. Touch "RECORD" while monitoring to record the status of the item being monitored. To stop recording, touch "STOP".
ACTIVE TEST
Operation Procedure
1. Touch "ACTIVE TEST" on "SELECT DIAG-MODE" screen.
2. Touch item to be tested, and check operation.
3. Touch "START".