4. Pressure Sensor System
Inspection 4 Pressure Sensor SystemINSPECTION PROCEDURE
1. SELF-DIAGNOSIS RESULT CHECK
Check self-diagnosis results.
Is the above displayed in the self-diagnosis display items?
YES >> GO TO 2.
NO >> Inspection End
2. CONNECTOR INSPECTION
1. Disconnect pressure sensor connector E50 and VDC/TCS/ABS control unit connector, check the terminals for deformation, disconnection, looseness, and so on. If there is an error, repair or replace the terminal.
2. Reconnect the connectors and Re-conduct VDC/TCS/ABS control unit self-diagnosis.
OK or NG
OK >> The connector terminal contact is loose, damaged, open or shorted.
NG >>GO TO 3.
3. PRESSURE SENSOR HARNESS INSPECTION
1. Turn ignition switch OFF and disconnect Pressure sensor connector E50 and VDC/TCS/ABS control unit connector.
2. Check the continuity between VDC/TCS/ABS control unit connector and pressure sensor connector.
OK or NG
OK >> GO TO 4.
NG >> If the open or short in harness, repair or replace the harness.
4. PRESSURE SENSOR INSPECTION
1. Connect pressure sensor and VDC/TCS/ABS control unit connectors.
2. Use "Data Monitor" to check the pressure sensor value.
OK or NG
OK >> Inspection End
NG >> If the pressure sensor is damaged or malfunctioning, replace the VDC actuator (pressure sensor it built inch).