Initial Inspection and Diagnostic Overview
Component InspectionFUEL PUMP
1. Disconnect "fuel level sensor unit and fuel pump" harness connector.
2. Check resistance between "fuel level sensor unit and fuel pump" terminals 1 and 3.
Resistance: 0.2 - 5.0 Ohms [at 25 °C (77 °F)]
CONDENSER
1. Disconnect condenser harness connector.
2. Check resistance between condenser terminals 1 and 2.
Resistance: Above 1 M Ohms [at 25 °C (77 °F)]