With Manufacturer's Scan Tool
CONSULT-II Inspection Procedure"MULTI REMOTE ENT"
CAUTION: If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be detected in self-diagnosis depending on control unit which carry out CAN communications.
1. Turn ignition switch OFF.
2. Connect CONSULT-II and CONSULT-II CONVERTER to the data link connector.
3. Turn ignition switch ON.
4. Touch "START (NISSAN BASED VHCL)".
5. Touch "BCM".
6. Touch "MULTI REMOTE ENT".
7. Select diagnosis mode. "DATA MONITOR", "ACTIVE TEST" and "WORK SUPPORT" are available.