ECM Harness Connector Terminal Layout
ECM Harness Connector Terminal LayoutECM Terminals and Reference Value
PREPARATION
1. ECM is located behind the glove box. For this inspection, remove glove box.
2. Remove ECM harness connector.
3. When disconnecting ECM harness connector, loosen it with levers as far as they will go as shown at right.
4. Connect a break-out box (SST) and Y-cable adapter (SST) between the ECM and ECM harness connector.
- Use extreme care not to touch 2 pins at one time.
- Data is for comparison and may not be exact.
ECM INSPECTION TABLE
ECM Harness Connector Terminal Layout Part 1:
ECM Harness Connector Terminal Layout Part 1:
ECM Harness Connector Terminal Layout Part 2:
ECM Harness Connector Terminal Layout Part 3:
ECM Harness Connector Terminal Layout Part 4:
ECM Harness Connector Terminal Layout Part 5:
ECM Harness Connector Terminal Layout Part 6:
ECM Harness Connector Terminal Layout Part 7:
ECM Harness Connector Terminal Layout Part 8:
ECM Harness Connector Terminal Layout Part 9:
Specification data are reference values and are measured between each terminal and ground. Pulse signal is measured by CONSULT-II.
CAUTION: Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in damage to the ECMs transistor. Use a ground other than ECM terminals, such as the ground.