C1109
ABS/TCS Control Unit Power and Ground Systems InspectionINSPECTION PROCEDURE
1. SELF-DIAGNOSIS RESULT CHECK
Check self-diagnosis results.
Is the above displayed in the self-diagnosis item?
YES >> GO TO 2.
NO >> Inspection End.
2. CONNECTOR INSPECTION
1. Turn the ignition switch OFF and disconnect the ABS actuator and electric unit (control unit) connector E125.
2. Check the terminals for deformation, disconnection, looseness or damage.
OK or NG
OK >>GO TO 3.
NG >> Repair or replace as necessary.
3. ABS/TCS CONTROL UNIT POWER AND GROUND CIRCUIT INSPECTION
Measure the voltage and continuity between the ABS actuator and electric unit (control unit) connector E125 and ground.
OK or NG
OK >> Check the battery for loose terminals, low voltage, etc. Repair as necessary.
NG >> Repair the circuit.