Auxiliary Mechanism: Temperature Setting Trimmer
Function Confirmation Procedure (Steps 1 - 6):
Function Confirmation Procedure (Steps 7 - 9):
Function Confirmation Procedure (Steps 10 - 12):
Function Confirmation Procedure (Step 13):
Function Confirmation Procedure (Steps 14):
FUNCTION CONFIRMATION PROCEDURE
AUXILIARY MECHANISM: TEMPERATURE SETTING TRIMMER
The trimmer compensates for differences in range of ±3 °C (±6 °F) between temperature setting (displayed digitally) and temperature felt by driver.
Operating procedures for this trimmer are as follows:
- Begin Self-diagnosis STEP 5 mode. Refer to "A/C System Self-diagnosis Function".
- Press top of fan control switch to set system in auxiliary mode.
- Display shows 61 in auxiliary mechanism. It takes approximately 3 seconds.
- Press top of temperature switch (driver side) as desired. Temperature will change at a rate of 0.5 °C (1.0 °F) each time the switch is pressed.
When battery cable is disconnected, trimmer operation is canceled. Temperature set becomes that of initial condition, i.e. 0 °C (0 °F).
AUXILIARY MECHANISM: FOOT POSITION SETTING TRIMMER
Air distribution ratio in FOOT mode can be set.
Operating procedures for this trimmer are as follows:
- Begin Self-diagnosis STEP 5 mode. Refer to "A/C System Self-diagnosis Function".
- Press top of fan control switch to set system in auxiliary mode.
- Display shows 61 in auxiliary mechanism. It takes approximately 3 seconds.
- Press the mode switch as desired.
AUXILIARY MECHANISM: INLET PORT MEMORY FUNCTION
When ignition key is turned from OFF to ON, inlet port can be set to AUTO or manual.
Operating procedures for this trimmer are as follows:
- Begin Self-diagnosis STEP 5 mode. Refer to "A/C System Self-diagnosis Function".
- Press top of fan control switch to set system in auxiliary mode.
- Display shows 61 in auxiliary mechanism. It takes approximately 3 seconds.
- Press the recirculation (REC) and fresh (FRE) switch as desired.