Changing A/T Fluid1. Run the engine to warm up the transaxle until the fluid is at full operating temperature of 50° - 80°C (122° - 176°F).
2. Stop the engine.
3. Drain the A/T fluid by removing the drain plug. Reinstall the drain plug to the specified torque using a new drain washer.
Drain plug: Refer to "Components".
4. Refill the transaxle with new specified A/T fluid through the A/T fluid charging pipe. Always refill the transaxle with the same volume amount that was drained out.
CAUTION: Do not overfill the transaxle.
Fluid grade and capacity: Refer to "Fluids and Lubricants".
5. Run the engine at idle speed for five minutes.