Refrigerant Pressure Sensor / Switch: Service and Repair
Removal and Installation for Refrigerant Pressure SensorREMOVAL
1. Discharge the refrigerant. Refer to "HFC-134a (R-134a) Service Procedure".
2. Disconnect the refrigerant pressure sensor connector and remove the refrigerant pressure sensor from condenser.
CAUTION: Do not to damage the condenser fins.
INSTALLATION
Installation is in the reverse order of removal.
CAUTION: Apply compressor oil to the O-ring of the refrigerant pressure sensor when installing it.
Refrigerant pressure sensor : 9.8 - 11.7 Nm (1.0 - 1.2 kg-m, 7.3 - 8.6 ft-lb)