Component Tests and General Diagnostics
POWER SUPPLY AND GROUND CIRCUITEC-MAIN-01:
Wiring Diagram
Diagnostic Procedure (Steps 1 - 2):
Diagnostic Procedure (Steps 3 - 5):
Diagnostic Procedure (Steps 6 - 9):
Diagnostic Procedure (Steps 10 - 12):
Diagnostic Procedure (Steps 13 - 17):
Diagnostic Procedure
Component Inspection
ECM RELAY
1. Apply 12 V direct current between ECM relay terminals 1 and 2.
2. Check continuity between relay terminals 3 and 5, 6 and 7.
3. If NG, replace ECM relay.