Intake Door
INTAKE DOORIntake Door Cable Adjustment
1. Remove instrument lower finisher.
2. Remove outer cable of intake door cable (1) from clamp (A).
3. Set intake door lever to REC position.
4. Push intake door link (2) in the direction shown by the arrow, and then carefully pull outer cable to controller side, and install clamp (A).
5. Operate intake door lever to insure that inner cable moves smoothly.
CAUTION: When clamping the outer cable, do not move the inner cable.