Refrigerant Pressure Sensor / Switch: Service and Repair
Removal and Installation of Refrigerant Pressure SensorREMOVAL
1. Use the recovery/recycling equipment to evacuate the refrigerant.
2. Disconnect connector, and then remove refrigerant pressure sensor (1) from condenser (2).
CAUTION: When working, be careful not to damage the condenser fins.
INSTALLATION
Installation is in the reverse order of removal.
CAUTION:
- Replace O-rings of refrigerant pressure sensor with a new one, and apply compressor oil when installing.
- When recharging refrigerant, check for leaks.