Component Inspection (Shift Lock Unit)
SHIFT LOCK SYSTEM
Component Inspection (Shift Lock Unit)
1.CHECK SHIFT LOCK UNIT
Apply voltage to terminals 1 and 2 of shift lock unit connector, and then check that shift lock unit is activated.
CAUTION:
Connect the fuse between the terminals when applying the voltage.
Can the plate be moved up and down?
YES - INSPECTION END
NO - Replace shift lock unit. Refer to Exploded View.