Diagnosis Procedure
BATTERY SAVER OUTPUT/POWER SUPPLY CIRCUIT
Description
Provides the battery saver output/power supply. Also cuts the power supply when the interior room lamp battery saver is activating.
BATTERY SAVER OUTPUT/POWER SUPPLY CIRCUIT
Diagnosis Procedure
1.CHECK BATTERY SAVER OUTPUT/POWER SUPPLY CIRCUIT OUTPUT
CONSULT-III
1. Turn ignition switch ON.
2. Select "BATTERY SAVER" of BCM (BATTERY SAVER) active test item.
3. While operating the test item, check voltage between BCM connector M17 terminal 4 and ground.
Is the inspection result normal?
YES - GO TO 2
NO - Replace BCM. Refer to BCM (Body Control Module).
2.CHECK BATTERY SAVER OUTPUT/POWER SUPPLY CIRCUIT OPEN
1. Turn ignition switch OFF.
2. Disconnect the following connectors.
- BCM M17
- Front room/map lamp assembly
- Vanity mirror lamp LH
- Vanity mirror lamp RH
- Trunk room lamp
- Step lamp LH
- Step lamp RH
3. Check continuity between BCM connector M17 terminal 4 and each interior room lamp connector.
Is the inspection result normal?
YES - GO TO 3
NO - Repair the harness or connectors.
3.CHECK BATTERY SAVER OUTPUT/POWER SUPPLY CIRCUIT SHORT
Check continuity between BCM connector M17 terminal 4 and ground.
Is the inspection result normal?
YES - Replace the interior room lamp. Refer to Service and Repair.
NO - Repair the harness or connectors.