Procedures
PARK/NEUTRAL POSITION (PNP) SWITCH
Inspection and Adjustment
INSPECTION
1. Shift the control lever to the "N" (Neutral) position.
2. Check position of PNP switch. The PNP switch position indicator (A) should point to the neutral position line (B) on the PNP switch as shown.
ADJUSTMENT
1. Put the control lever in the "N" position.
2. Loosen the PNP switch bolts (A).
3. Align the PNP switch position indicator (A) with the neutral position line (B).
4. Tighten the PNP switch bolts (A).