Roof Warning Lamp Does Not Illuminate When Soft Top Operates
ROOF WARNING LAMP DOES NOT ILLUMINATE WHEN SOFT TOP OPERATES
Description
Roof warning lamp does not illuminate when soft top operates.
ROOF WARNING LAMP DOES NOT ILLUMINATE WHEN SOFT TOP OPERATES
Diagnosis Procedure
1.CHECK ROOF WARNING LAMP SIGNAL
Check roof warning lamp signal circuit. B176B.
Is the inspection result normal?
YES - GO TO 2.
NO - Repair or replace malfunctioning parts.
2.REPLACE SOFT TOP CONTROL UNIT
Replace soft top control unit. Diagnosis Procedure.
Is the inspection result normal?
YES - INSPECTION END
NO - Check intermittent incident. Intermittent Incident.