Soft Top Does Not Operate Using Roof Open/Close Switch
SOFT TOP DOES NOT OPERATE USING ROOF OPEN/CLOSE SWITCH
Description
Soft top does not operate using roof open/close switch.
SOFT TOP DOES NOT OPERATE USING ROOF OPEN/CLOSE SWITCH
Diagnosis Procedure
1.CHECK TRUNK ROOM LAMP SIGNAL
Check trunk room ramp switch circuit. Diagnosis Procedure.
Is the inspection result normal?
YES - GO TO 2.
NO - Repair or replace the malfunctioning parts.
2.CHECK BACK-UP LAMP SIGNAL
Check back-up lamp circuit. Component Function Check.
Is the inspection result normal?
YES - GO TO 3.
NO - Repair or replace the malfunctioning parts.
3.CHECK ROOF OPEN/CLOSE SWITCH
Check roof open/close switch circuit. Component Function Check.
Is the inspection result normal?
YES - GO TO 4.
NO - Repair or replace the malfunctioning parts.
4.REPLACE SOFT TOP CONTROL UNIT
Replace soft top control unit. Removal And Installation.
Is the inspection result normal?
YES - INSPECTION END
NO - Check intermittent incident. Intermittent Incident.