Component Function Check
TRUNK ROOM LAMP CIRCUIT
Component Function Check
CAUTION:
Before performing the diagnosis, check that the following is normal.
- Battery saver output/power supply
- Trunk room lamp bulb
1.CHECK TRUNK ROOM LAMP OPERATION
CONSULT-III
1. Turn ignition switch ON.
2. Select "LUGGAGE LAMP TEST" of BCM (INT LAMP) active test item.
3. While operating the test item, check that trunk room lamp turns ON/OFF.
Is the inspection result normal?
YES - Trunk room lamp circuit is normal.
NO - Diagnosis Procedure.