Sedan Without Intelligent Key
TRUNK LID OPENER ACTUATOR
Description
Performs trunk lid open with signal from BCM.
TRUNK LID OPENER ACTUATOR
Diagnosis Procedure
Regarding Wiring Diagram information, refer to Sedan Without Intelligent Key.
1.CHECK OUTPUT CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect trunk lamp switch and trunk release solenoid connector.
3. Check voltage between trunk lamp switch and trunk release solenoid connector and ground.
Is the inspection result normal?
YES - GO TO 4
NO - GO TO 2
2.CHECK OUTPUT SIGNAL
Check voltage between BCM connector and ground.
Is the inspection result normal?
YES - Repair or replace harness.
NO - GO TO 3
3.CHECK TRUNK LID OPENER ACTUATOR CIRCUIT
1. Disconnect BCM.
2. Check continuity between BCM connector and trunk lamp switch and trunk release solenoid connector.
3. Check continuity between BCM connector and ground.
Is the inspection result normal?
YES - Replace BCM. Refer to BCM.
NO - Repair or replace harness.
4.CHECK TRUNK LID OPENER GROUND CIRCUIT
Check continuity between trunk lamp switch and trunk release solenoid connector and ground.
Is the inspection result normal?
YES - Replace trunk lamp switch and trunk release solenoid.
NO - Repair or replace harness.