S Terminal Circuit
S TERMINAL CIRCUIT
Description
The output voltage of the generator is controlled by the IC regulator at terminal "3" (S) detecting the input voltage from battery. Terminal "3" circuit detects the battery voltage to adjust the generator output voltage with the
IC regulator.
S TERMINAL CIRCUIT
Diagnosis Procedure
Regarding Wiring Diagram information. Refer to Coupe or Sedan.
1.CHECK VOLTAGE REGULATOR CIRCUIT CONNECTION
Check to see if connector F7 terminal 3 is clean and tight.
Is the inspection result normal?
YES - GO TO 2
NO - Repair terminal connection. Confirm repair by performing complete Starting/Charging system test. Refer to diagnostic station instruction manual.
2.CHECK VOLTAGE REGULATOR CIRCUIT
Check voltage between generator harness connector F7 terminal 3 and ground.
3 - ground Battery voltage
Does battery voltage exist?
YES - Refer to Work Flow.
NO - Check harness for open between generator and fuse.