Inspection And Adjustment
TRANSAXLE ASSEMBLY
Inspection and Adjustment
INSPECTION BEFORE INSTALLATION
After installing the torque converter to the CVT, be sure to check distance (A) to ensure it is within specifications.
Distance (A) : 14.4 mm (0.567 in)
INSPECTION AFTER INSTALLATION
Check the following.
- Check for CVT fluid leakage and check CVT fluid level. Refer to CVT RE0F10A.
- Check CVT position. Refer to CVT RE0F10A.
- Start and warm up the engine. Visually check that there is no leakage of engine coolant and CVT fluid.
ADJUSTMENT AFTER INSTALLATION
Erase TCM data.
- Erase CVT fluid degradation level data. Refer to CONSULT-III Function (Transmission).
- When replacing the transaxle assembly, erase EEP ROM in TCM. Refer to CVT RE0F09B.