Operation CHARM: Car repair manuals for everyone.

Diagnosis Description





DIAGNOSIS SYSTEM (METER)


Diagnosis Description


SELF-DIAGNOSIS MODE
- Segment display operation can be checked in self-diagnosis mode.
- Meters/gauges can be checked in self-diagnosis mode.

OPERATION PROCEDURE
1. Turn ignition switch ON, and switch the trip meter to "trip A" or "trip B".

NOTE:
If the diagnosis function is activated with "trip A" displayed, the mileage on "trip A" is reset to "0000.0".
(The same way for "trip B".)
2. Turn ignition switch OFF.





3. While pressing the trip reset switch (1), turn ignition switch ON again.
4. Make sure that the trip meter displays "0000.0".
5. Press the trip reset switch at least 3 times. (Within 7 seconds after the ignition switch is turned ON.)
6. The unified meter control unit is turned to self-diagnosis mode.
- Speedometer and tachometer return to zero, simultaneously.





- All of the segments of engine coolant temperature gauge, fuel gauge, odo/trip meter, shift position indicator (A) for A/T models and information display illuminate.

NOTE:
For M/T models, start-up lamp (B) illuminate instead of shift position indicator.

NOTE:
- Check combination meter power supply and ground circuit when the self-diagnosis mode of the combination meter does not start. Replace combination meter if power supply and ground circuit are normal.
- If any of the segments are not displayed, replace combination meter.
7. Each meter activates by pressing the trip reset switch.






NOTE:
- If any of the meters or gauges is not activated, replace combination meter.
- The figure is reference.