Diagnosis Procedure
TRUNK LAMP SWITCH
Description
Detects trunk open/close condition.
TRUNK LAMP SWITCH
Diagnosis Procedure
Regarding Wiring Diagram information, Intelligent Key System.
1.CHECK TRUNK LAMP SWITCH INPUT SIGNAL
1. Turn ignition switch OFF.
2. Check voltage between BCM connector and ground.
Is the inspection result normal?
YES - GO TO 4
NO - GO TO 2
2.CHECK TRUNK LAMP SWITCH CIRCUIT
1. Disconnect BCM connector.
2. Check continuity between BCM connector and trunk lamp switch and trunk release solenoid connector.
3. Check continuity between BCM connector and ground.
Is the inspection result normal?
YES - GO TO 3
NO - Repair or replace harness between BCM and trunk lamp switch and trunk release solenoid.
3.CHECK TRUNK LAMP SWITCH GROUND CIRCUIT
Check continuity between trunk lid lock assembly connector and ground.
Is the inspection result normal?
YES - GO TO 4
NO - Repair or replace trunk lamp switch and trunk release solenoid ground circuit.
4.CHECK BCM OUTPUT SIGNAL
1. Insure trunk remains closed during this step.
2. Connect BCM connector.
3. Check voltage between BCM connector and ground.
Is the inspection result normal?
YES - GO TO 5
NO - Replace BCM. Body Control System.
5.CHECK TRUNK ROOM LAMP SWITCH
Component Inspection.
Is the inspection result normal?
YES - GO TO 6
NO - Replace trunk lamp switch and trunk release solenoid.
6.CHECK INTERMITTENT INCIDENT
Intermittent Incident.
- Inspection End.