Component Inspection (Shift Lock Relay)
SHIFT LOCK SYSTEM
Component Inspection (Shift Lock Relay)
1.CHECK SHIFT LOCK RELAY
1. Apply battery voltage between terminals 2 and 1 of the shift lock relay.
CAUTION:
Connect a fuse between the terminals when applying battery voltage.
2. Check continuity between shift lock relay terminals 5 and 3.
Is the inspection result normal?
YES - Inspection End
NO - Replace shift lock relay.