Insufficient Cooling
TROUBLE DIAGNOSIS
Insufficient Cooling
SYMPTOM: Insufficient cooling
INSPECTION FLOW
1.CONFIRM SYMPTOM BY PERFORMING OPERATIONAL CHECK - TEMPERATURE DECREASE
1. Turn temperature control dial counterclockwise to maximum cold position.
2. Check for cold air at discharge air outlets.
Can the symptom be duplicated?
YES - GO TO 3.
NO - GO TO 2.
2.CHECK FOR ANY SYMPTOMS
Perform a complete operational check for any symptoms. Operational Check.
Does another symptom exist?
YES - How To Perform Trouble Diagnosis For Quick And Accurate Repair.
NO - System OK.
3.CHECK FOR SERVICE BULLETINS
Check for any service bulletins.
- GO TO 4.
4.CHECK COMPRESSOR DRIVE BELT TENSION
Check compressor belt tension. Procedures (MR20DE) or Procedures (QR25DE).
OK or NG
OK - GO TO 5.
NG - Adjust or replace compressor belt. Adjustments (MR20DE) or Adjustments (QR25DE).
5.CHECK AIR MIX DOOR OPERATION
Check and verify air mix door mechanism for smooth operation in each mode.
Does air mix door operate correctly?
YES - GO TO 6.
NO - Repair or replace as necessary.
6.CHECK COOLING FAN MOTOR OPERATION
Check and verify cooling fan motor for smooth operation. .
Does cooling fan motor operate correctly?
YES - GO TO 7.
NO - Check cooling fan motor. .
7.CHECK RECOVERY/RECYCLING EQUIPMENT BEFORE USAGE
Check recovery/recycling equipment before connecting to vehicle. Verify there is no pressure in the recovery/recycling equipment by checking the gauges. If pressure exists, recover refrigerant from equipment lines.
- GO TO 8.
8.CHECK REFRIGERANT PURITY
1. Connect recovery/recycling equipment to vehicle.
2. Confirm refrigerant purity in supply tank using recovery/recycling and refrigerant identifier.
OK or NG
OK - GO TO 9.
NG - Check contaminated refrigerant. Contaminated Refrigerant.
9.CHECK FOR REFRIGERANT PRESSURE
Check refrigerant pressure with manifold gauge connected. Refer to "TEST READING".
OK or NG
OK - Perform diagnostic work flow. Refer to "DIAGNOSTIC WORK FLOW".
NG - GO TO 10.
10.CHECK FOR EVAPORATOR FREEZE UP
Start engine and run A/C. Check for evaporator freeze up.
Does evaporator freeze up?
YES - Perform diagnostic work flow. Refer to "DIAGNOSTIC WORK FLOW".
NO - GO TO 11.
11.CHECK AIR DUCTS
Check ducts for air leaks.
OK or NG
OK - If the symptom still exists, perform a complete operational check. Operational Check. If other symptoms exist, How To Perform Trouble Diagnosis For Quick And Accurate Repair.
NG - Repair air leaks.
DIAGNOSTIC WORK FLOW
PERFORMANCE CHART
Test Condition
Testing must be performed as follows:
TEST READING
Recirculating-to-discharge Air Temperature Table
Ambient Air Temperature-to-operating Pressure Table
TROUBLE DIAGNOSIS FOR ABNORMAL PRESSURE
Whenever system's high and/or low side pressure is abnormal, diagnose using a manifold gauge. The marker above the gauge scale in the following tables indicates the standard (normal) pressure range. Since the standard (normal) pressure differs from vehicle to vehicle, refer to Ambient Air Temperature-to-operating Pressure
Table above.
Both High- and Low-pressure Sides are Too High
High-pressure Side is Too High and Low-pressure Side is Too Low
High-pressure Side is Too Low and Low-pressure Side is Too High
Both High- and Low-pressure Sides are Too Low
Low-pressure Side Sometimes Becomes Negative
Low-pressure Side Becomes Negative