Pre Start Check List





Check List

1. Turn the Ignition ON.





NOTE:

With the ignition ON, the meter will light up and the odometer will display the mileage.

2. Turn ON the CONSULT PC (do not start C-III plus at this time).

^ The first time the reprogramming kit (PC converter box) is attached to either of the C-III USB ports, the following screens (Figures 1b - 1d) will display.

^ If this is not the first time, these screens will not display - go to step 3.





a. Select Install the software automatically (Recommended).

b. Select Next.





c. Select Continue Anyway.





d. Select Finish.

e. Disconnect and then reconnect the USB cable at the CONSULT PC.





3. The left side LED on the Reprogramming tool should be ON and Green (see Figure 1e).

^ LED is Green; go to the next step.

^ LED is not ON or is Red the Reprogramming Tool may need repair. Call Tech-Mate at 1-800-662-2001 for assistance.

4. Open/start ASIST.





5. Select Specialty Tools and then C11 Odometer Calibration Tool.

6. After selecting C11 Odometer Calibration Tool, C-III plus will launch automatically.





7. Wait for the plus VI to be recognized.

^ Serial number will display when the plus VI is recognized.





8. Select Diagnosis (All Systems).





9. Make sure VIN or Chassis # matches the vehicle's VIN.

10. Select Confirm.

11. Wait for a few seconds while the progress bar completes.





12. The C11 Odometer Calibration Tool will launch automatically (Figure 1j)

13. The VIN will automatically display.

^ Make sure the displayed VIN matches the vehicle's VIN.

14. Enter the Technician Name (use the CONSULT PC keyboard).

15. Select Start.





16. Select I Agree.

^ After selecting "I Agree" the reprogramming / calibration process will begin automatically and take only a few seconds to complete.

If the calibration process does not complete within 1 minute, or an error message is displayed:

a. Turn the ignition OFF.

b. Turn the CONSULT PC OFF.

c. Make sure all cables and tools are securely connected.

^ Refer to Prepare for Reprogramming, steps 1-5.

^ Disconnect and securely reconnect all tools, cables, and connections.

d. Make sure the Internet connection is working.

e. Go back to Reprogram the Meter, and restart.





17. When the calibration process has completed successfully, the message in Figure 1L will display.

18. Turn the ignition OFF

19. Select Continue.

20. Wait for 2 minutes.





^ The screen in Figure 1m will display with a 2 minute countdown.





21. After waiting 2 minutes, the "Calibration Completion Report" will display (Figure 1n).

22. Print the "Calibration Completion Report" and attach it to the repair order for warranty documentation.

23. Select Exit.