The Fuel Gauge Pointer Does Not Move
THE FUEL GAUGE POINTER DOES NOT MOVE
Description
Fuel gauge needle will not move from a certain position.
Diagnosis Procedure
1.CHECK COMBINATION METER INPUT SIGNAL
1. Select "METER/M&A" on CONSULT-III.
2. Using "FUEL METER" of "DATA MONITOR", compare the monitor value with the fuel gauge reading on the combination meter. Fuel Level Sensor Signal Circuit.
Does monitor value match fuel gauge reading?
YES - GO TO 2
NO - Replace combination meter. Removal And Installation.
2.CHECK FUEL LEVEL SENSOR SIGNAL CIRCUIT
Check the fuel level sensor signal circuit. Fuel Level Sensor Signal Circuit.
Is the inspection result normal?
YES - GO TO 3
NO - Repair harness or connector.
3.CHECK FUEL LEVEL SENSOR UNIT
Perform a unit check for the fuel level sensor unit. Fuel Level Sensor Signal Circuit.
Is the inspection result normal?
YES - GO TO 4
NO - Replace fuel level sensor unit. Removal and Installation.
4.CHECK FLOAT INTERFERENCE
Check that the float arm does not interfere or bind with any of the components in the fuel tank.
Is the inspection result normal?
YES - Replace combination meter. Removal And Installation.
NO - Repair or replace malfunctioning parts.