Interior Room lamps
POWER SUPPLY AND GROUND CIRCUIT:_:BCM
Diagnosis Procedure
Regarding Wiring Diagram information, [1][2]Body Control Systems.
1. CHECK FUSE AND FUSIBLE LINK
Check if the following BCM fuse or fusible link are blown.
Is the fuse or fusible link blown?
YES - Replace the blown fuse or fusible link after repairing the affected circuit.
NO - GO TO 2
2. CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM.
3. Check voltage between BCM harness connector and ground.
Is the measurement normal?
YES - GO TO 3
NO - Repair or replace harness.
3. CHECK GROUND CIRCUIT
Check continuity between BCM harness connector and ground.
Does continuity exist?
YES - Inspection End.
NO - Repair or replace harness.
Special Repair Requirement
1. REQUIRED WORK WHEN REPLACING BCM
Initialize control unit. Refer to CONSULT-III operation manual.
- Work End.