Blower Fan ON Signal
BLOWER FAN ON SIGNAL
Component Function Check
1.CHECK BLOWER FAN ON SIGNAL
With CONSULT-III
1. Turn ignition switch ON.
2. Select "AIR CONDITIONER" of "BCM" using CONSULT-III.
3. Select "FAN ON SIG" in "DATA MONITOR" mode.
4. Check blower fan ON signal when the fan control dial is operated.
Is the inspection result normal?
YES - INSPECTION END
NO - SEE Diagnosis Procedure.
Diagnosis Procedure
1.CHECK BLOWER FAN ON SIGNAL
1. Turn ignition switch OFF.
2. Disconnect A/C auto amp. harness connector.
3. Turn ignition switch ON.
4. Check output waveform between A/C auto amp. and ground with using oscilloscope.
Is the inspection result normal?
YES - Replace A/C auto amp. Automatic Air Conditioner.
NO - GO TO 2.
2.CHECK BLOWER FAN ON SIGNAL CIRCUIT FOR OPEN
1. Turn ignition switch OFF.
2. Disconnect BCM connector.
3. Check continuity A/C auto amp. harness connector and BCM harness connector.
Is the inspection result normal?
YES - GO TO 3.
NO - Repair harness or connector.
3.CHECK BLOWER FAN ON SIGNAL CIRCUIT FOR SHORT
Check continuity between A/C auto amp. harness connector and ground.
Is the inspection result normal?
YES - Replace BCM. Removal And Installation With Intelligent Key System.
NO - Repair harness or connector.