EVAP Control System Pressure Sensor
DTC P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR
Wiring Diagram
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in damage to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
DTC P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR
Wiring Diagram
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in damage to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.