Trunk Room Lamp Circuit
TRUNK ROOM LAMP CIRCUIT
Description
Controls the trunk room lamp (ground side) to turn the luggage room lamp ON and OFF.
Component Function Check
CAUTION:
Before performing the diagnosis, check that the following is normal.
- Interior room lamp power supply
- Trunk room lamp bulb
1. CHECK TRUNK ROOM LAMP OPERATION
CONSULT ACTIVE TEST
1.Turn the ignition switch ON.
2.Select "LUGGAGE LAMP TEST" of BCM (INT LAMP) active test item.
3.With operating the test items, check that trunk room lamp turns ON/OFF.
On: Trunk room lamp ON
Off: Trunk room lamp OFF
Does the Trunk room lamp turn ON/OFF?
YES- Trunk room lamp circuit is normal.
NO- .
Diagnosis Procedure
1. CHECK TRUNK ROOM LAMP OUTPUT
CONSULT ACTIVE TEST
1.Turn the ignition switch OFF.
2.Remove trunk room lamp bulb.
3.Turn the ignition switch ON.
4.Select "LUGGAGE LAMP TEST" of BCM (INT LAMP) active test item.
5.With operating the test item, check continuity between BCM harness connector and the ground.
Is the measurement value normal?
YES- GO TO 2.
Fixed ON-GO TO 3.
Fixed OFF-Replace BCM.
2. CHECK TRUNK ROOM LAMP OPEN CIRCUIT
1.Turn the ignition switch OFF.
2.Disconnect BCM connector and trunk room lamp connector.
3.Check continuity between BCM harness connector and trunk room lamp harness connector.
Does continuity exist?
YES- Replace the trunk room lamp.
NO- Repair the harnesses or connectors.
3. CHECK TRUNK ROOM LAMP SHORT CIRCUIT
1.Turn the ignition switch OFF.
2.Disconnect BCM connector and trunk room lamp connector.
3.Check continuity between BCM harness connector and the ground.
Does continuity exist?
YES- Repair the harnesses or connectors.
NO- Replace BCM.