Heating And Air Conditioning
DIAGNOSIS AND REPAIR WORKFLOW
Work Flow
OVERALL SEQUENCE
DETAILED FLOW
1. INTERVIEW FOR MALFUNCTION
Interview the symptom to the customer.
- GO TO 2.
2. SYMPTOM CHECK
Check the symptom from the customer's information. Check that any symptom occurs other than the interviewed symptom.
Insufficient cooling/heating-GO TO 3.
Refrigerant leakage-GO TO 6.
Noise- GO TO 7.
3. CONTROL SYSTEM DIAGNOSIS
Perform the system diagnosis for the A/C control system.
- Automatic Air Conditioning. (Automatic air conditioning)
- Manual Air Conditioning. (Manual air conditioning)
Is A/C control system normal?
YES- GO TO 4.
NO- GO TO 8.
4. PERFORMANCE TEST
Perform the performance test. Check the operation of each part. Performance Test.
- GO TO 5.
5. TROUBLE DIAGNOSIS FOR UNUSUAL PRESSURE
Diagnose using a manifold gauge whenever system's high and/or low side pressure(s) is/are unusual. Specify the malfunctioning part. Symptom Table.
Low refrigerant charge-GO TO 6.
Except above-GO TO 8.
6. CHECK REFRIGERANT FOR LEAKAGES
Check refrigerant for leakages. Specify the malfunctioning part. Leak Test.
- GO TO 8.
7. TROUBLE DIAGNOSIS FOR NOISE
Perform trouble diagnosis for noise. Specify the malfunctioning part. Noise.
- GO TO 8.
8. MALFUNCTION PART REPAIR
Repair or replace the malfunctioning part.
- GO TO 9.
9. REPAIR CHECK (OPERATION CHECK)
Check the operation of each part.
Does it operate normally?
YES- INSPECTION END
NO- GO TO 2.