Hazard Switch
HAZARD SWITCH
Component Function Check
1. CHECK HAZARD SWITCH SIGNAL BY CONSULT
CONSULT DATA MONITOR
1.Turn the ignition switch ON.
2.Select "HAZARD SW" of BCM (FLASHER) data monitor item.
3.With operating the hazard switch, check the monitor status.
Is the inspection result normal?
YES- Hazard switch circuit is normal.
NO- .
Diagnosis Procedure
1. CHECK HAZARD SWITCH SIGNAL INPUT
1.Turn ignition switch OFF.
2.Disconnect hazard switch connector.
3.Check voltage between hazard switch connector and ground.
Is the inspection result normal?
YES- GO TO 4.
NO- GO TO 2.
2. CHECK HAZARD SWITCH SIGNAL OPEN CIRCUIT
1.Disconnect BCM connector.
2.Check continuity between hazard switch harness connector and BCM harness connector.
Is the inspection result normal?
YES- GO TO 3.
NO- Repair or replace harness.
3. CHECK HAZARD SWITCH SIGNAL SHORT CIRCUIT
Check continuity between hazard switch harness connector and ground.
Is the inspection result normal?
YES- Replace BCM. With Intelligent Key System (With Intelligent Key) or Service and Repair (Without Intelligent Key).
NO- Repair or replace harness.
4. CHECK HAZARD SWITCH GROUND OPEN CIRCUIT
Check continuity between hazard switch harness connector and ground.
Is the inspection result normal?
YES- Replace hazard switch.
NO- Repair or replace harness.