Precaution For Liquid Gasket
PRECAUTIONS
Precaution for Liquid Gasket
REMOVAL OF LIQUID GASKET
- After removing nuts and bolts, separate the mating surface, using Tool and remove old liquid gasket.
Tool number: KV-10111100 (J-37228)
CAUTION:
Be careful not to damage the mating surfaces.
- Tap Tool to insert it (1), and then slide it by tapping on the side (2)
as shown.
- In areas where Tool is difficult to use, use plastic hammer to lightly tap the parts, to remove it.
CAUTION:
Do not damage the mating surfaces.
LIQUID GASKET APPLICATION PROCEDURE
1.Remove old liquid gasket adhering to the liquid gasket application surface and the mating surface, using scraper.
- Remove liquid gasket completely from the groove of the liquid gasket application surface, bolts, and bolt holes.
2.Thoroughly clean the mating surfaces and remove adhering moisture, grease and foreign materials.
3.Attach liquid gasket tube to Tool.
Tool number: WS-39930000 (-)
Use Genuine RTV Silicone Sealant or equivalent. Recommended Chemical Products And Sealants.
4.Apply liquid gasket without breaks to the specified location with the specified dimensions.
- If there is a groove for the liquid gasket application, apply liquid gasket to the groove.
- Apply the liquid gasket to the inner side of the bolt holes unless the procedure instructions indicate to apply to the outer side of the bolt holes.
- Install the mating component within five minutes of the liquid gasket application.
- Then allow 30 minutes for the liquid gasket to set before filling the engine with oil or coolant.
- If liquid gasket protrudes, wipe it off immediately.
- Do not retighten nuts or bolts after the five minutes have elapsed.
CAUTION:
Carefully follow all of the warnings, cautions, notes, and procedures contained in this manual.