Air Mix Door
TROUBLE DIAGNOSIS
Air Mix Door
SYMPTOM: Air mix door does not change.
INSPECTION FLOW
1. CONFIRM SYMPTOM BY PERFORMING OPERATIONAL CHECK - TEMPERATURE INCREASE
1.Turn the temperature control dial clockwise until maximum heat.
2.Check for hot air at discharge air outlets.
- GO TO 2.
2. CONFIRM SYMPTOM BY PERFORMING OPERATIONAL CHECK - TEMPERATURE DECREASE
1.Turn the temperature control dial counterclockwise until maximum cold.
2.Check for cold air at discharge air outlets.
Is the inspection results normal?
YES- GO TO 4.
NO- GO TO 3.
3. PERFORM COMPLETE OPERATIONAL CHECK
Perform a complete operational check and check for any symptoms. Operational Check.
Is the inspection results normal?
YES- How To Perform Trouble Diagnosis For Quick And Accurate Repair.
NO- System OK.
4. CHECK FOR SERVICE BULLETINS
Check for any service bulletins.
- GO TO 5.
5. CHECK AIR MIX DOOR CONTROL LINKAGE
Check and verify air mix door mechanism for smooth operation.
OK or NG
OK- If the symptom still exists, perform a complete operational check. Operational Check If other symptoms exist, How To Perform Trouble Diagnosis For Quick And Accurate Repair.
NG- Repair or adjust air mix door control linkage. Air Mix Door Cable Adjustment.