Programming and Relearning
POWER WINDOW SYSTEM
Power Window Auto Operation Initialization
1.Turn the ignition switch ON.
2.Open the window-all the way DOWN.
3.Pull all the way UP on the switch and hold (close the window).
- Continue holding the switch all the way UP for 4 seconds after the window is closed.
4.Confirm the window is now operating correctly.
NOTE:
- If the window is still not operating correctly, Symptom Related Diagnostic Procedures.
- The above initialization procedure must be performed if any of the following occur:
- Battery cable is disconnected
- Power window switch connector is disconnected
- Power window regulator is replaced
- Power window motor is replaced
- Window glass is removed
- Window glass run rubber is replaced
- Power window fuse is blown
- Window is partly opened and/or closed many times without being fully closed.