Manual Air Conditioning
REFRIGERANT PRESSURE SENSOR
Removal and Installation for Refrigerant Pressure Sensor
REMOVAL
CAUTION:
- Do not damage the condenser fins.
- Perform lubricant return operation before each refrigeration system disassembly. However, if a large amount of refrigerant or lubricant is detected, never perform lubricant return operation. Perform Oil Return Operation.
1.Move air guide aside.
2.Disconnect the refrigerant pressure sensor connector.
3.Remove the refrigerant pressure sensor (1) from the liquid tank on the condenser.
INSTALLATION
Installation is in the reverse order of removal.
CAUTION:
- Replace O-ring with new one. Then apply compressor oil to them when installing.
- Check for leakages when recharging refrigerant. Leak Test