Special Repair Requirement
INSPECTION AND ADJUSTMENT
ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair Requirement
INITIALIZATION PROCEDURE
If the moonroof does not open or close automatically, use the following procedure to return moonroof operation to normal.
NOTE:
If the moonroof switch is released at any time during step 4, the procedure must be started over again. Leave the ignition switch ON for at least 2 seconds after this procedure.
1.Push the ignition switch to the ON position.
2.Hold the moonroof switch in the tilt up position. Release the switch when the moonroof has reached the full tilt up position.
3.Hold the moonroof switch in the tilt up position again. After a delay, the moonroof will backup. Release the switch.
4.Within 4 seconds of releasing the switch in step 3, hold the moonroof switch in the tilt up position again.
The moonroof will move from the full tilt-up --> slide-close --> slide-open --> slide-close --> tilt-up --> slide close. Release the switch, initialization is complete if the moonroof operates normally.
ANTI-PINCH FUNCTION
1.Fully open the moonroof to the full open position.
2.Place a piece of wood at the fully closed position.
3.Close the moonroof completely with auto-slide close function.
4.Moonroof should make contact and then tilt up in reverse for 100mm (3.94 in.) (approx.).
CAUTION:
- Do not test the anti-pinch function with your hands or other part of body parts because they may be pinched.
- Depending on environment and driving conditions, if a similar impact or load is applied to the moonroof it may lower.
- Test the auto-slide operation before inspection when the system initialization is performed.
- Perform the initialization procedure when the auto-slide operation or anti-pinch function does not operate normally.