Removal And Installation
CONDENSER
REFRIGERANT PRESSURE SENSOR : Removal and Installation
REMOVAL
1.Discharge the refrigerant. Refer to "Recycle Refrigerant" Recycle Refrigerant.
2.Remove the front fascia. Refer to "Removal and Installation" Removal And Installation.
3.Remove the refrigerant pressure sensor (1) from the liquid tank on the condenser.
CAUTION:
Do not damage the condenser fins.
INSTALLATION
Installation is in the reverse order of removal.
CAUTION:
- Do not reuse the O-rings.
- Apply A/C compressor oil to the new O-rings for installation.
- After charging refrigerant, check for leaks. Refer to "Leak Test" Leak Test.