Charging System Preliminary Inspection
CHARGING SYSTEM PRELIMINARY INSPECTION
Diagnosis Procedure
1. CHECK BATTERY TERMINALS CONNECTION
Check if battery terminals are clean and tight.
Is the inspection result normal?
YES- GO TO 2.
NO- Repair battery terminal connection. Confirm repair by performing complete Charging system test using EXP-800 NI or GR8-1200 NI (if available). Refer to the applicable Instruction Manual for proper testing procedures.
2. CHECK FUSE
Check for blown fuse and fusible link.
Is the inspection result normal?
YES- GO TO 3.
NO- Replace the blown fuse or fusible link after repairing the affected circuit.
3. CHECK GENERATOR GROUND TERMINAL CONNECTION
Check if connector F7 terminal 4 is clean.
Is the inspection result normal?
YES- GO TO 4.
NO- Repair connection.
4. CHECK DRIVE BELT TENSION
Check drive belt tension. Refer to "Removal and Installation" Service and Repair.
Is the inspection result normal?
YES- Inspection End.
NO- Repair as needed.